Wondering which refurbished GE ultrasound machine to go for? How do the features, applications, probes availability, imaging modes and general system details compare between GE Voluson P8, GE Logiq P5 and GE Logiq P3? Here is a simple comparison to help you decide.
PrimedeQ offers used or refurbished ultrasound machines. Click here for checking out multiple options or call +917019759765 or +918971223957.
Applications – Refurbished GE ultrasound machine
Particulars
Voluson P8
LogiQ p5
LogiQ P3
Applications
Abdominal
Yes
Yes
Yes
Bowel Imaging
No
No
No
Contrast Imaging _ Cardiac (High or Low MI)
No
Yes
No
Contrast Imaging _ General Imaging (Low MI)
No
Yes
No
Echocardiography_Adult
Yes
Yes
No
Echocardiography_Neonate
No
Yes
No
Echocardiography_Pediatric
No
Yes
Yes
Fetal Echo
Yes
No
No
Internal Medicine w/ Shared Service
Yes
Yes
No
Interventional Cardiology
No
No
No
Interventional Radiology
No
Yes
Yes
MSK/Anesthesiology
Yes
Yes
Yes
OB
Yes
Yes
Yes
Pediatrics
No
Yes
No
Shear Wave Elastography
No
No
No
Small Parts (Breast, Thyroid, Testis…)
Yes
Yes
Yes
Strain Elastography
No
Yes
No
Stress Echocardiography
No
Yes
No
Surgery
No
Yes
Yes
TCD(Transcranial)
No
Yes
No
Transesophageal Echo_Adult
No
No
No
Transesophageal Echo_Pediatric
No
No
No
Urology (Renal, Prostate…)
No
Yes
Yes
Vascular
Yes
Yes
Yes
Women’s Health Care (GYN & Breast)
Yes
Yes
Yes
Probes / Tranducers –
Refurbished GE ultrasound machine
Particulars
Voluson P8
LogiQ p5
LogiQ P3
Transducers
2D Arrary 3D Convex (1~6Mhz)
No
No
No
2D Arrary 3D Phased Array (1~5Mhz)
No
No
No
2D Array 3D TEE (2~7Mhz)
No
No
No
3D Convex (2~6Mhz)
Yes(RAB2-6-RS)
Yes
No
3D Convex Light Weight (2~7Mhz)
No
No
No
3D Endocavity (3~10Mhz)
Yes(RIC5-9W-RS)
Yes
No
3D Linear (4~18Mhz)
No
No
No
3D Micro Convex (3~9Mhz)
No
Yes
No
Convex (1~6Mhz)
Yes(4C-RS)
Yes
Yes
Convex (2~9Mhz)
No
No
No
Endocavity_Curved Type (5~8Mhz)
Yes(E8C-RS)
Yes
Yes
Hockey stick (<13Mhz)
No
No
No
Hockey stick (>13Mhz)
No
No
No
ICE (Intracardiac Echo Cardiography)
No
No
Linear (<9Mhz)
No
Yes
Yes
Linear (>14Mhz)
No
No
No
Linear (3~12Mhz)
Yes(12L-RS)
Yes
Yes
Linear 25mm
No
No
No
Linear 50mm
No
No
No
Micro Convex (5~8Mhz)
No
Yes
Yes
Pencil CW (2Mhz)
No
Yes
No
Pencil CW (5 or 6Mhz)
No
Yes
No
Phased Array_Adult (1~5Mhz)
Yes(3Sc-RS)
Yes
Yes
Phased Array_Neonate (4~12Mhz)
No
Yes
No
Phased Array_Pediatric (3~8hz)
No
Yes
Yes
Single Crystal Convex (1~6Mhz)
No
No
No
Single Crystal Convex (2~9Mhz)
No
No
No
Single Crystal Endocavity_Straight Type (3~10Mhz)
No
No
No
Single Crystal Linear (<9Mhz)
No
No
No
Single Crystal Linear (>14Mhz)
No
No
No
Single Crystal Linear (3~12Mhz)
No
No
No
Single Crystal Phased Array_Adult (1~5Mhz)
Yes
No
No
Single Crystal Phased Array_Pediatric (3~8hz)
No
No
No
T or L shape Intra Operative
No
Yes
Yes
TEE_Adult (3-7Mhz)
No
No
No
TEE_Pediatric (3~7Mhz)
No
No
No
Features – Refurbished GE ultrasound machine
Particulars
Voluson P8
LogiQ p5
LogiQ P3
Features
Auto Follicle 2D Measurement
Yes
Yes
Auto Follicle 3D Measurement
Yes
No
No
Auto Image Opt(B mode)
Yes
Yes
Yes
Auto Image Opt(Doppler)
No
Yes
Yes
Auto IMT
No
Yes(Option)
No
Auto IMT (Real Time)
No
No
No
Auto NT Measurement (=Sono NT)
Yes
No
No
Automated B/M/D Measurement
No
Yes
No
Automated LH Measurement(Automated Function Imaging(AFI), Cardiac Motion Quantification(CMQ), or Auto EF(Ejection Fraction)
No
Yes
No
Barcode Reader
No
No
No
Flexible Report
Yes
Yes
Yes
Fusion
No
No
No
Gel Warmer
No
No
No
Live Dual (B/BC) Mode
No
Yes
No
Needle Enhancement or Needle Recognition
No
No
No
Raw Data File
Yes
Yes
Yes
SmartExam or Scan Assistant
No
Yes
No
Spatial Compounding(=CrossXbeam)
Yes
Yes
Yes
Speckle Reduction (=SRI)
Yes
Yes
Yes
Tissue Harmonic Imaging
Yes
Yes
Yes
Triplex Mode
Yes
Yes
Yes
Write Zoom
Yes
Yes
Yes
Imaging Modes
Particulars
Voluson P8
LogiQ p5
LogiQ P3
Imaging Modes
2D, M mode
Yes
Yes
Yes
Anatomical M-mode
Yes
Yes
Yes
B Flow
Yes
Yes
No
Bi-directional Power (=HD FLOW)
Yes
Yes
No
Color, Power Angio, Pulse Wave Doppler
Yes
Yes
Yes
Contrast Imaging – Cardiac
No
Yes(Option)
No
Contrast Imaging – General Imaging
No
Yes(Option)
No
Freehand 3D
Yes
Yes
Yes
HD Live
Yes
No
No
Live 3/4D OB/GYN
Yes
Yes(Option)
No
Live 3D Echo
No
No
No
M-color Flow Mode
Yes
Yes
Yes
Panoramic Imaging (=Logiq view)
Yes(XTD)
Yes(Option)
Yes
SCW Doppler
Yes
Yes(Option)
No
Shear Wave Elastography
No
No
No
STIC (Spatio-Temporal Image Correlation)
No
No
No
Strain and Strain Rate (Cardiac)
No
No
No
Strain-based Elastography
No
Yes(Option)
No
Stress Echo
No
Yes(Option)
No
Tissue Doppler(Velocity) Imaging
No
Yes(BT11+)
No
Trapezoidal Mode
Yes
Yes
Yes
Connectivity
Particulars
Voluson P8
LogiQ p5
LogiQ P3
Connectivity
DICOM 3.0
Yes
Yes(Option)
Yes
DICOM SR_Cardiac
Yes
Yes(Option)
Yes(Option)
DICOM SR_OB/GYN
Yes
Yes(Option)
Yes(Option)
DICOM SR_Vascular
Yes
Yes(Option)
Yes(Option)
DVD/CD RW
Yes
Yes
Yes
HDD/SDD
500GB
250GB
Available
JPEG, WMV, & AVI
Yes
Yes
Yes
USB
Yes
Yes
Yes
Wireless LAN
No
No
No
System Overview
Particulars
Voluson P8
LogiQ p5
LogiQ P3
System Overview
Battery
Yes
No
No
Cart (HCU)
No
No
No
CP Back-Lighting
–
Yes
Yes
Estimated Market Price ($)
Economy
Economy
Economy
Independent Steer & Lockable Wheels
Yes
Yes
Yes
Maximum Depth of Field
30cm
30cm
30cm
Minimum Depth of Field
0-1cm
0-2cm
0-2cm
Monitor (inch)
17″ LCD
15″LCD
15″ LCD
Monitor Display
1280 * 1024
1024*768
1024 * 768
Probe Ports
3
3
2(3rd port option)
Sleep Mode (Quick Start)
Yes
Tilt/Rotate Adjustable Monitor
Tilt / Rotate only
Yes
Yes
Touch Screen (Inch)
No
No
No
Trackball or Trackpad
Trackball
Trackball
Trackball
Weight
143lbs(65Kg)
165lbs(75kg)
176lbs(80kg)
Year Launched
2012
2006
2008
Good refurbished GE ultrasound machine are available in the voluson and logiq series and even more recent versana series. Contact us for refurbished GE ultrasound machine anywhere in India.
Disclaimer : All views and information in this site and the blogs is based on secondary information available in public domain and is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information. PrimedeQ is not responsible for any errors or omissions, or for the results obtained from the use of this information. Readers are encouraged to independently verify all required information.